Energy Saving Design
●According to environment and load capacity, auto adjustment to achieve the optimal heating mode and reduce energy consumption.
●New synthetic silica gel seal provides exceptional sealing with heat loss prevention and 25% energy saving.
Internal Circulation System
●Solenoid valve replaces manual knob, avoids the first shutdown of the vacuum pump makes the pump oil sucked backward to chamber.
●Turbine suction fan and plates with heat dissipating holes, give higher ventilation and better temperature uniformity.
●Vacuum pump with power socket and solenoid valve switch control
●Solenoid valve air-exhaust is switch controlled.
Humanized Design
●LCD display of real-time parameters, and menu setting of temperature, illumination and time
●Detachable and height-adjustable plates with min height of 30mm
●Slide-way bayonet prevents the plates tilt and dislocation.
●Radiable heating ensures temperature uniformity.
●Large arc angle, easy to clean and maintain
●Display of "END" with buzz reminder
●Power off memory
●℃/℉convertible
●Switch controls
Safety System
●Limited temperature alarm system: auto-stop if limited temperature exceeds and auto audible and visual alarm if alarm-temperature exceeds.
●Electric leakage protection device ensures the safety of the operator and other equipment in the laboratory.
●Double-layer airtight door with inner toughened glass and outer bio-glass window,
●Self diagnostic function: display fault information and facilitate troubleshooting.
Model | GOV25V | GOV50V | GOV50VS | GOV90V |
Volume (L/cu.ft.) | 25/0.88 | 50/1.77 | 50/1.77 | 90/3.18 |
Plate Qty (Height Adjustable) | 1 | 2 | 2 | 2 |
Load Capacity/Plate | 10kg | |||
Chamber Size (mm) | 300*300*275 | 415*370*345 | 415*370*345 | 450*450*450 |
Outer Size (mm) | 500*450*790 | 610*510*850 | 610*510*850 | 660*600*1500 |
Package Size (mm) | 570*620*950 | 730*630*1010 | 730*630*1010 | 780*720*1660 |
Net Weight/Gross Weight (kg) | 40/45 | 60/70 | 55/65 | 160/175 |
CBM | 0.34 | 0.47 | 0.47 | 0.94 |
Performance | ||||
Temperature Control Range | RT+10~200℃ | RT+10~200℃ | Vacuum only, no heating | RT+10~200℃ |
Temperature Accurancy | 0.1℃ | |||
Temperature Fluctuation | ±1℃ | |||
Vacuum Level | 100pa | |||
Ambient Temperature | 5℃ ~ 40℃ | |||
Timming Range | 1~9999min | |||
Control | ||||
Display | LCD Display | |||
Controller | Microprocessor | |||
Sensor | PID | |||
Heating Pipe | Stainless steel | |||
Construction | ||||
Outer Material | Laser-cutting cold-rolled steel with anti-static spraying | |||
Chamber Material | Corrosion-resistant brushed stainless steel | |||
Plate | One-time formed 304 stainless steel entire plate, no welding spot; Load-bearing beam at the bottom, gives strong bearing capacity. | |||
Insulation | High quality aluminum silicate flutter cotton. | |||
Observation Window | Double-layer toughened glass window with rubber ring | |||
Electrical and Noise Level | ||||
Power Supply | 220V/50HZ | |||
Power Consumption | 500W | 1440W | No heating | 2800W |
Power Code | 0.75² | 1.5² | 0.75² | 1.5²/16A |
Standard | Electric leakage protection, Vacuum pump filters | |||
Options | ||||
1.Φ 25mm/Φ 50mm/Φ 80mm test holes | ||||
2.Multi-segment programmable controller | ||||
3.Independent temperature limiting controller | ||||
4.USB Port OR Printer OR RS232 OR RS485 and communication software |